+86-0431-84158222
+86-0431-84155885
S/N |
Item |
Unit |
parameters |
1 |
Rated voltage |
kV |
40.5 |
2 |
Main bus rated current |
A |
1250~2500 |
3 |
Branch bus rated current |
A |
1250~2500 |
4 |
Rated short-circuit open current |
kA |
31.5 |
5 |
Rated filling pressure |
kPa |
130 |
6 |
Phase to phase, phase-to-ground/ isolating fracture, 1min power-frequency voltage test |
kV |
95/118 |
7 |
Phase to phase, phase-to-ground/ isolating fracture, lightning impulse |
kV |
185/215 |
8 |
1min auxiliary and control circuit insulation tests |
kV |
2 |
9 |
Out-of-phase earth fault breaking current |
kA |
27.4 |
10 |
Short-time withstand current |
kA |
Main loop and grounding switch (device) 31.5kA-4s |
earth conductor and connection 27.4kA-2s |
|||
11 |
Peak withstand current |
kA |
Main loop and grounding device 80 |
Earth conductor and connection 69.6 |
|||
12 |
Temperature-rise test |
|
1.1*1250A、1.1*2500A |
13 |
Mechanical operation test |
|
Circuit breaker 10,000 times/ disconnector 3,000 times/ earthing switch 3,000 times |
14 |
Enclosure protection class verification |
|
IP4X |
15 |
IP grade of gas tank |
|
IPX7 (immersed) |
16 |
Arc burning test |
|
Switch chamber AFLR level 31.5kA-0.5s |
Bus chamber AFLR level 31.5kA-0.5s |
|||
Cable chamber AFLR level 31.5kA-0.5s |
Typical features:
1. Horizontal installation of direct-acting type three-position disconnecting
switch.
2. All operating mechanisms are installed outside the gas chamber.
3. Complete interlocking protection function, ensuring safe operation.
4. Bus plug and switch system for connection between cabinets.
5. Maximum current of 3150A, breaking current of 31.5KA.
Automatic control:
1. Adopting PLC logical control unit.
2. Adopting latest communication technology.
3. Realize man-machine interactive operation interface.
4. Efficient protection and control capability.
5. Simple interface, easy to operate.
Environmental restrictions:
1. HV live parts are fully sealed in the stainless steel gas chamber and can
fully adapt to any external environment.
2. Solid insulation and gas insulation technologies are adopted for live parts
inside and outside gas chamber.
3. Inner cone sleeve plug mode is adopted for cable accessory to prevent water
and dust.
4. All insulating material and sealing materials are adapt to a wide range of
high and low temperatures.
Interlocking protection:
1. To prevent falsely opening or closing circuit breaker.
2. To prevent switching on/off the disconnecting switch with load.
3. To prevent closing ground switch when electrified.
4. To prevent closing circuit breaker with ground lead.
5. To prevent falsely entering live space.